Selection Guide
UniMeasure manufactures seven linear and rotary variable displacement transducer series. Each series includes several models, with a number of measurement ranges and output options. Output is available in analog or digital square wave. Transducers are available to measure linear displacement.
Feature |
ZX Series |
FX Series |
LX Series |
Jx SERIES |
Standard Series |
HX Series |
RTX Series |
Measurement Parameter | Linear Position | Linear Position | Linear Position | Linear Position | Linear Position | Linear Position | Rotary Position |
Housing Construction | Aluminum | Thermoplastic | Thermoplastic | Thermoplastic | Aluminum | Aluminum Stainless Steel Thermoplastic | Aluminum Stainless Steel Thermoplastic |
Ingress Protection | IP-40 (NEMA 1) | IP-52 (NEMA 12) Optionally: IP-65 (NEMA 4X) | IP-40, (NEMA 1) | IP-52 (NEMA 12) Optionally: IP-65 (NEMA 4X) | IP-40 (NEMA 1) Optionally: IP-50 (NEMA 1) | IP-65 (NEMA 4x) Optionally: IP-68 (NEMA 6) | IP-65 (NEMA 4X) |
Integral Dust Protection | No | No | No | Yes | Optional | Yes | – |
Linearity (analog output) | ±1% FS | ±1% FS | ±0.25% FS to ±1% FS |
±0.25% FS to ±1% FS |
±0.25% FS to ±0.25% FS |
±0.25% FS to ±0.25% FS |
±0.30% FS |
Linearity (digital output) | – | – | ±0.10% FS | ±0.10% FS | ±0.03% FS | ±0.03% FS | – |
Measurement Ranges | 0 to 1.5″ (38 mm) | 0 to 2” (50 mm) to 0 to 15” (381 mm) |
0 to 2” (50 mm) to 0 to 50” (1.25 m) |
0 to 2” (50 mm) to 0 to 80” (2 m) |
0 to 2” (50 mm) to 0 to 80” (2 m) |
0 to 2” (50 mm) to 0 to 2000” (50 m) |
0 to 45 deg to 0 to 200 turns |
Typical Application Areas | Throttle Positioning Applications with Dithering and Vibration | Applications with Dithering and Vibration, Automotive Suspension, Steering, Brake and Throttle Positioning | CAT Scan Tables, Hospital Beds, Fume Hoods, Automotive Steering,Brake and Throttle Positioning | Automotive Suspension Concrete Metering Saw Blade Positioning Liquid Level Check Agricultural Product Testing | Conveyor Width Setting Injection Molding Machines Extrusion Presses Crash Testing | Valve Positioning Railroad Maintenance Equipment Flood & Irrigation Control Gates Textile Machinery | Rotary Valve Positioning Industrial Gate Positioning Rack and Pinion Systems Machining Equipment |
Available Outputs | |||||||
“A” Voltage Divider Circuit | Yes | – | Yes | Yes | Yes | Yes | Yes |
“B” Bridge Circuit | – | – | – | – | Yes | Yes | – |
“420” 4 to 20 mA | – | – | – | Yes | Yes | Yes | Yes |
“510” 10 VDC, ±10 VDC | – | – | – | Yes | Yes | Yes | Yes |
“EP” Digital | – | – | Yes | Yes | Yes | Yes | – |
“HM” Analog Voltage | Yes | Yes | – | – | – | – | – |
“V” Velocity Voltage | – | – | – | – | – | – | – |
“VP” Velocity /Position | – | – | – | – | – | – | – |